Sun Hydraulics FRDBXAN 流量控制阀
FRDBXAN - Fixed orifice, restrictive, pressure compensated flow control valve with bypass blocked
Sun Hydraulics
This valve is a 2 port restrictive flow control valve that fits into a 3 port cavity. There is no connection to port 2 of the cavity. Customer must specify a flow rating. Factory set flow ratings are within +/- 10% of the requested setting. Maximum pressure at port 3 should be limited to 3000 psi (210 bar). The sharp-edged orifice design minimizes flow variations due to viscosity changes. A tuneable adjustment control option provides up to +/- 25% variation from the nominal factory pre-set flow. Adjustment is done with +/- 3 turns of the adjust screw. Screw in (CW) to increase flow. Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations. Cavity T-2A Series 2 Capacity 12 gpm45 L/min. Maximum Operating Pressure 5000 psi350 bar Maximum Input Flow 30 gpm120 L/min. Valve Hex Size 1 1/8 in.28,6 mm Valve Installation Torque 45 - 50 lbf ft61 - 68 Nm Adjustment Screw Internal Hex Size 5/32 in.4 mm Locknut Hex Size 9/16 in.15 mm Locknut Torque 80 - 90 lbf in.9 - 10 Nm Model Weight .40 lb0,20 kg Seal kit - Cartridge Viton: 990-202-006 Show FAQ What happens if I block the bypass port on a priority flow control? The valve acts as a 2 port restrictive flow control. How big is a drop of hydraulic oil? There are exactly 250 Sun drops in a cubic inch or 15 in a cc. How accurate are Sun's flow controls? We claim +/- 10%. We set to +/- 5% in production testing to allow for differences in customers' conditions. If you want accuracy, stay in the bottom 2/3rds of the range. Our 12 gpm (45 L/min.) flow controls are quite flat at 9 gpm (34 L/min.) and dead flat below 6 gpm (23 L/min.), until you get to the bottom of the range. Below about .25 gpm (1 L/min.), spool leakage and orifice conditions start to limit accuracy. I have a heat problem, will Sun's priority flow control help? I am afraid not. Unless you are overflowing your current valve and correctly size ours, you are not likely to notice any improvement. Priority flow controls are not efficient devices. They are an easy way to get more than 1 source of oil from 1 pump but they can generate a lot of heat. Try to size your actuators so the pressures are similar on both the priority and the bypass circuits. If you can't do that, try to have the lower flow leg be the lower pressure. The pump pressure is determined by whichever leg is higher and if there is flow that is taking a pressure drop that is not doing work it is creating heat. What happens if I block the control flow (priority) port? All flow is blocked, hence the term priority. The priority flow has to be satisfied. What is the compensating pressure of Sun's flow controls? The spring force in our flow controls equates to about 100 psi (7 bar). This is high enough to give the valves acceptable capacity (not really) and not too high for proper circuit operation. 100 psi (7 bar) is the spring force; at the upper end of the flow control's range, the drop through the valve will be as high as 250 psi (17 bar) before it starts modulating. What is the pressure drop through a flow control? In a meter-in flow control circuit if the pump is set at 3000 psi and the load is 2000 psi the drop through the flow control is 1000 psi. In a meter-out circuit with the load at 2000 psi the drop through the flow control is 2000 psi. Related Files Technical TipsTechnical Tips for Manufacturing Sun Cartridge Cavities (522.27 KB) Sun's Floating Style Screw-In Cartridge (719.9 KB) Sun Model Code Explanation; 999-901-334 (343.9 KB)
Home / Sun Hydraulics - FRDBXAN - Fixed orifice, restrictive, pressure compensated flow control valve with bypass blocked