KDRC1HC2 电机控制-产品快照
- 品牌:
- KDRC1HC2
- 型号:
- KDRC1HC2
- 重量:
- 9.534 kg
* 所有产品信息均源于第三方公开数据或用户上传,工业链仅整合供参考,真实价格货期请联系供应商确认.
供应商名称 | 电话 | 备注 |
---|---|---|
暂无展示,可咨询在线客服 | 400-811-6961 | 微信咨询,as10@gchane.com , QQ3350168184 |
产品介绍
KDRC1HC2 电机控制
KDRC1HC2 TCI 25HP KDR NEMA1 LINE/LOAD 460VAC HIGH Z REACTOR
KDRC1HC2
Catalog Number: KDRC1HC2 Description: KDR,460VAC,HIGH-Z,NEMA1,LINE/LOAD REACTOR Rated HP: 25 Rated Amps: 34 Ship Weight: 21 lbs.
TCI Products are normally stocked. Standard Lead time is 3-4 business days after ARO. For expedited needs please contact our sales team. Use KDR High “Z” Units For: Any application where a 5% reactor would be applied. Reduction of nuisance tripping caused by: Transient voltages caused by capacitor switching Line notching DC bus overvoltage tripping Inverter overcurrent and overvoltage Additional benefits include: Lowering injected percentage of harmonic current Improving true power factor Reducing cross-talk between drives Adding impedance to drives with DC link chokes/reactors when more impedance is desired due to a relatively stiff source TCI KDR units will help prevent inverter instantaneous overcurrent trips because they provide needed inductance when the load on an inverter has an abnormally high capacitance. This product is recommended when lengths between the Variable Frequency Drive and motor are between 25 thru 100 feet. These guidelines have been recommended because as motor leads become longer, the resonant frequency is lowered, and the magnitude and duration of the voltage spikes increases. For lead lengths exceeding 100 feet, TCI offers V1k Output Filters and KMG MotorGuard High Performance Output Filters for long lead motor protection needs. Optimized Drive Reactors Extend the life of the motor on the Output: • Dampen Overshoot Peak Voltage • Reduce Motor Heating • Reduce Audible Noise • RoHS Compliant! Dampen Overshoot Peak Voltage: KDR Optimized Drive Reactors may be used at the output of AC-PWM variable frequency drives where the motor lead lengths are less than 100 feet. The addition of a KDR unit to the output of a drive will dampen overshoot peak voltage, reduce motor heating and audible noise, helping to extend the life of the motor. TCI KDR Line Reactors reduce harmonic current, Increases life of drive and Protects sensitive equipment. Harmonics and Power Quality Stabilization: Variable frequency drives are beneficial to a wide range of applications, but contain a power conversion process that creates current and voltage distortion which can cause system-wide problems, including: Transformer and distribution equipment overheating Random breaker tripping Sensitive equipment may fail completely Poor power factor Reduced system efficiency The addition of a KDR Reactor will reduce harmonic content, which reduces the total RMS current, thereby improving the total power factor. Nuisance tripping is less common Drive uptime is increased Power factor is improved A voltage transient, commonly caused by capacitor bank switching (or other issues), sends a current surge into the VFD bus capacitor. The additional current raises bus voltage, thus causing a drive fault (trip). In addition, this overvoltage condition will cause the drive to shut down in order to protect its components. Unbalanced Distribution Systems cause Nuisance Tripping : Input voltage phase unbalance may prevent the drive from performing due to subsequent overcurrent conditions which cause the drive to cease operating. KDR Optimized Line Reactor on Unbalanced systems The addition of a KDR Reactor to the input of every drive will help balance the drive input line currents. 5% Impedance Protection Ambient Temperature: 50° C (122° F) - Open; 40° C (104° F) - Enclosed Altitude (Maximum): 2,000 meters (6,000 feet) Derating necessary above 2,000 meters Fundamental Frequency: 50/60 Hz Short Term Overload Rating: Tolerate 200% rated I for a minimum of 3 minutes This unit is NOT UL Listed. Inductance Characteristics: Minimum 95% L at 110% Load Minimum 80% L at 150% Load
Motor Controls