Electrical Specifications Control Voltage 115VAC +/- 10%; 50-60 Hz Transient Protection(Internal) 2500 V for 10ms Power Consumption 3 Watts (Maximum) Communication Ports Setup Baud Rate Protocol Available Addresses Serial Interface 1 Port for MS777 Even Parity 1 Stop Bit 9600 Modbus RTU 01 RS485 1 Port for PC, PLC,etc. None, Odd, or Even Parity 1 or 2 Stop Bits 300 - 28800 Modbus RTU A01 - A99 RS485 1 Port for MS777 Even Parity 1 Stop Bit 9600 Modbus RTU 01 RS485 1 Port for PC, PLC,etc. None, Odd, or Even Parity 1 or 2 Stop Bits 300 - 28800 Modbus RTU A01 - A99 RS485 Real-time Clock Y2K Battery Back-up Life Last fault memory Compliant 10 years @ 25 degrees Celsius without external power Stores up to 4 faults with time and date stamp, includes voltages and currents at the time of trip Output Relays (option 1) Configuration Contact Material Pilot Duty Rating General Purpose Rating Consult Factory for Function of Relays Two Independent Electro-Mechanical Form C(SPDT) Silver/Tin Oxide 240 VA @ 120 VAC 5 A @ 120 VAC Analog Output (option 2) Types Output Signal Maximum Load 0-20 mA 4-20 mA 0-10 VDC 0-5 VDC Accuracy Isolation 0-20 mA, 4-20 mA, 0-5 VDC, 0-10 VDC (specify with order, for others consult factory) KW, PF, Amps, or Volts (Software Selectable) 500 Ohms max. 500 Ohms max. 2 kilo Ohms min. 2 kilo Ohms min. +/- 1% @ 25 degrees Celsius 1 kVrms Analog/Digital Inputs (option 3) Consult Factory Physical Specifications Certifications UL cUL. CE UL 508 cUL 508. Pending Environment Class of Protection Ambient Operating Temp. Ambient Storage Temperature Humidity NEMA 3R, UL Type 12 -20 - 70 degrees Celsius -30 - 70 degrees Celsius Up TO 85%, non-condensing Enclosure Dimensions Weight Material 6.1" L x 6.5" W X 1.1" D 1.2 lbs. Black Polycarbonate Display Size Lighting Liquid Crystal with extended temp range 2 rows x 20 characters LED Back-Light Keypad Mechanical Life Overlay Material UV Exposure without degredation Terminal Eight 0.5" stainless steel dome buttons for tactile feedback 50,000 actuation's Polyester 2000 Hrs. Depluggable terminal block 2 4-20 mA pressure transducer inputs with adjustable full scale ranges. Down Hole Transducer Full Scale Annulus Transducer Full Scale Adjustable Turn Off Set Point Adjustable Turn On Set Point Adjustable Minimum Off Time 50-600 psi in 5 psi steps 15-600 psi in 5 psi steps 10-245 ft. in 5 ft. steps 15-250 ft. in 5 ft. steps 2-250 minutes Real time display shows actual head level with the turn on & turn off setpoints. 2 Pressure Transducer Inputs Accuracy/Range Field calibrate for 0-20mA, 4-20mA, 0-5V or 1-5V Note: 250 ½ or less shunt resistor must be used with current output transducers Maximum input voltage 5V Input Impedance 10 k½ Standard (250 ½ available for fixed current inputs) Optional Turbine Flowmeter Input w/built in signal conditioner Sensitivity 20mv - 30V BW 3 kHz Total Output Readings Displayed 16,777,215 gal or barrels Read via the Network 4,294,967,295 gal/102,261,126 barrels Flow Readings Instantaneous Flow in barrels/day (bpd) Output for last 24 hours (barrels) Low / No Flow Shutdown with adjustable time delay Trip delay 1 - 255 min 100 ½ RTD Input Max Temp 400° C / 752° F Accuracy ± 2%
Motor Controls